0.9 / 1.6 / 8-14 / 3.43 / 3.9 / 4.2 / 5.1 / 7.9 µm smart process infrared thermometer up to 2000°C, optics 160-1 and 100-1
0.9 / 1.6 / 8-14 / 3.43 / 3.9 / 4.2 / 5.1 / 7.9 µm smart process infrared thermometer up to 2000°C, optics 160-2
0.9 / 1.6 / 8-14 / 3.43 / 3.9 / 4.2 / 5.1 / 7.9 µm smart process infrared thermometer up to 2000°C, optics 100-2
0.9 / 1.6 / 8-14 / 3.43 / 3.9 / 4.2 / 5.1 / 7.9 µm smart process infrared thermometer up to 2000°C, optics 160-3
0.9 / 1.6 / 8-14 / 3.43 / 3.9 / 4.2 / 5.1 / 7.9 µm smart process infrared thermometer up to 2000°C, optics 390-1, 460-1, 510-1 & 790-1
0.9 / 1.6 / 8-14 / 3.43 / 3.9 / 4.2 / 5.1 / 7.9 µm smart process infrared thermometer up to 2000°C, optics 814-3
0.9 / 1.6 / 8-14 / 3.43 / 3.9 / 4.2 / 5.1 / 7.9 µm smart process infrared thermometer up to 2000°C, optics 814-5
0.9 / 1.6 / 8-14 / 3.43 / 3.9 / 4.2 / 5.1 / 7.9 µm smart process infrared thermometer up to 2000°C, optics 814-6
0.9 / 1.6 / 8-14 / 3.43 / 3.9 / 4.2 / 5.1 / 7.9 µm smart process infrared thermometer up to 2000°C, optics 510-2
0.9 / 1.6 / 8-14 / 3.43 / 3.9 / 4.2 / 5.1 / 7.9 µm smart process infrared thermometer up to 2000°C, optics 814-1
0.9 / 1.6 / 8-14 / 3.43 / 3.9 / 4.2 / 5.1 / 7.9 µm smart process infrared thermometer up to 2000°C, optics 814-2

RAYOMATIC 40

picto fleche 0.9 / 1.6 / 8-14 / 3.43 / 3.9 / 4.2-4.8 / 5.1 / 7.9 µm smart process infrared thermometer up to 2000°C, digital communication signal

The smart process infrared thermometers IRtec RAYOMATIC 40 can measure temperatures up to 2000°C. IRtec RAYOMATIC 40 have a 2-wire 4-20 mA linear output signal with a superimposed digital communication signal.

  • 4-20 mA output signal with superimposed digital signal
  • Remote control by computer
  • Emissivity adjustable by PC
  • Advanced signal processing: Emissivity, peak-picker, valley-picker, peak hold, valley hold and averaging
  • Optional laser pointing system
Ask a question
Get a call

The smart process infrared thermometers IRtec RAYOMATIC 40 can measure temperatures up to 2000°C. Compact, rugged and reliable, the different models of the series can be equipped with various optics offering different spectral responses, which meets the requirements of a large number of standard and specialized industrial applications. 

IRtec RAYOMATIC 40 have a 2-wire 4-20 mA linear output signal with a superimposed digital communication signal. They can be used as a transmitter and can be easily connected to any standard indicator, data acquisition system or control panel. The digital signal allows communication with a computer or a dedicated communicator, for instrument remote configuration and calibration.

rayo20The emissivity value can be adjusted by PC from 0.30 to 1.00.

An optional integrated laser pointer system facilitates the identification of the measured surface area.

Applications:

IRtec RAYOMATIC 40 series is suitable for a wide range of manufacturing and processing industry applications: ferrous and non-ferrous metals, glass, minerals, ceramics, chemicals, electronics and research and development. 

Key features:

  • 4-20 mA output signal with superimposed digital signal
  • Remote control by computer
  • Emissivity adjustable by PC
  • Advanced signal processing: Emissivity, peak-picker, valley-picker, peak hold, valley hold and averaging
  • Optional laser pointing system

Infrared temperature measurement

Models100-1100-2160-1160-2160-3
Temperature range600 to 1600°C300 to 1300°C
Spectral response0.9 µm1.6 µm
Diameter @ distance6 mm @ 500 mm16 mm @ 1 m6 mm @ 500 mm3 mm @ 300 mm2 mm @ 100 mm
Accuracy±0.5% RDG
Repeatability±0.25% RDG
Response time28 ms

 

Models814-1814-2814-3814-5814-6
Temperature range(-25) to 1000°C0 to 1000°C0 to 800°C0 to 400°C
Spectral response8 - 14 µm
Diameter @ distance21 mm @ 600 mm9 mm @ 300 mm3.5 mm @ 150 mm80 mm @ 1 m10 mm @ 65 mm
Accuracy±1% RDG
Repeatability±0.5% RDG
Response time100 ms

 

Models343-1390-1460-1510-1510-2790-1
Temperature range100 to 400°C600 to 1300°C400 to 1600°C150 to 1300°C800 to 2000°C100 to 1000°C
Spectral response3.43 µm3.90 µm4.2 to 4.8 μm5.1 µm7.9 µm
Diameter @ distance26 mm @ 500 mm17 mm @ 550 mm6.5 mm @ 300 mm17 mm @ 550 mm
Accuracy±1% RDG
Repeatability±0.5% RDG
Response time1 s100 ms1 s

Further features

EmissivityAdjustable from 0.30 to 1.00
Stability±0.45°C/°C beyond operating limits
Working temperatureFrom -20°C to +60°C (0 to 50°C for laser)
Calculation functionsAverage, max, min, diff, ambient temperature compensation
LaserRed pointing laser
Digital communicationSuperimposed digital signal to 4-20 mA
Output4-20 mA 2-wire current loop – max load 700 W

Optics

RAYOMATIC-40_Optics-160-1-et-100-1RAYOMATIC-40_Optics-160-2
RAYOMATIC40_Optics-100-2RAYOMATIC40_Optics-160-3
RAYOMATIC40_Optics-390-1-460-1-510-1-et-790-1RAYOMATIC40_Optics-814-3
RAYOMATIC40_Optics-814-5RAYOMATIC40_Optics-814-6
RAYOMATIC40_Optics510-2RAYOMATIC40_Optics814-1
RAYOMATIC40_Optics-814-2 

 

General specifications

Size∅45 x 200 mm
Weight of electronic module0.5 Kg
Power supply12 to 32 VDC
InterfacesRS 232

Environmental specifications

Reference conditions23°C ±5°C
Storage conditionsModels 814-x: +10°C to 70°C
Further models: -30°C to +70°C
IP protectionIP 65

 

Instruments:

Ordering code structure: 1140-XXX – A – B – C – D – E / X

Please select the required options from tables A, B… below to define the right device reference.

1140-100           IRtec RAYOMATIC 40_0.9 µm: +600°C to 1600°C

Table A – Range - Optics

1                      +600 to 1600°C – 6 mm at 500 mm

2                      +600 to 1600°C – 16 mm at 1000 mm

Table B – Output signal

2                      Linear 4-20 mA with smart digital communication

Table C – Pinpointing system

0                      None

1                      Laser with dot spot

Table D – 4-20 mA connection cable

1                      2 m long shielded cable

2                      8 m long shielded cable

9                      Special length upon request

Table E – Calibration report

NO                   None

EC                   Factory traceable calibration report

Table X – Personal settings

ENG                 English instruction manual

FRA                 French instruction manual

 

1140-160           IRtec RAYOMATIC 40_1.6 µm: +300°C to 1300°C

Table A – Range - Optics

1                      +300 to 1300°C – 6 mm at 500 mm

2                      +300 to 1300°C – 3 mm at 300 mm

3                      +300 to 1300°C – 2 mm at 100 mm

Table B – Output signal

2                      Linear 4-20 mA with smart digital communication

Table C – Pinpointing system

0                      None

1                      Laser with dot spot

Table D – 4-20 mA connection cable

1                      2 m long shielded cable

2                      8 m long shielded cable

9                      Special length upon request

Table E – Calibration report

NO                   None

EC                   Factory traceable calibration report

Table X – Personal settings

ENG                 English instruction manual

FRA                 French instruction manual

 

1160-814           IRtec RAYOMATIC 40_8-14 µm

Table A – Range - Optics

1                      -25 to 1000°C – 21 mm at 600 mm

2                      0 to 1000°C – 9 mm at 300 mm

3                      0 to 1000°C – 3.5 mm at 140 mm

5                      0 to 800°C – 80 mm at 1000 mm

6                      0 to 400°C – 10 mm at 65 mm

Table B – Output signal

2                      Linear 4-20 mA with smart digital communication

Table C – Pinpointing system

0                      None

1                      Laser with dot spot

Table D – 4-20 mA connection cable

1                      2 m long shielded cable

2                      8 m long shielded cable

9                      Special length upon request

Table E – Calibration report

NO                   None

EC                   Factory traceable calibration report

Table X – Personal settings

ENG                 English instruction manual

FRA                 French instruction manual

 

1140 510           IRtec RAYOMATIC 40_5.1 µm

Table A – Range - Optics

1                      -150 to 1300°C – 17 mm at 550 mm

2                      -800 to 2000°C – 8.5 mm at 300 mm

Table B – Output signal

2                      Linear 4-20 mA with smart digital communication

Table C – Pinpointing system

0                      None

1                      Laser with dot spot

Table D – 4-20 mA connection cable

1                      2 m long shielded cable

2                      8 m long shielded cable

9                      Special length upon request

Table E – Calibration report

NO                   None

EC                   Factory traceable calibration report

Table X – Personal settings

ENG                 English instruction manual

FRA                 French instruction manual

 

1160                 IRtec RAYOMATIC 40_Special waveband 

Table A – Range - Optics

343-1                3.43 µm - 400 to 1600°C – 17 mm at 550 mm

390-1                3.9 µm - 600 to 1300°C – 17 mm at 550 mm

460-1                4.6 µm - 400 to 1600°C – 17 mm at 550 mm

790-1                7.9 µm - 40 to 600°C – 17 mm at 550 mm

Table B – Output signal

2                      Linear 4-20 mA with smart digital communication

Table C – Pinpointing system

0                      None

1                      Laser with dot spot

Table D – 4-20 mA connection cable

1                      2 m long shielded cable

2                      8 m long shielded cable

9                      Special length upon request

Table E – Calibration report

NO                   None

EC                   Factory traceable calibration report

Table X – Personal settings

ENG                 English instruction manual

FRA                 French instruction manual

 

Accessories:

Air Purge and Miscellaneous

EE280315          DN100 1" 1/2 adapter flange for EE290075 M44x1.5 + Window holder

EE280328          DN100 flange for EE290075 M44x1.5

EE280329          DN100 1" 1/2 adapter flange for EE290075 M44x1.5

EE290072          2 axis orientable support

EE290074          1 axis orientable support

EE290075          Water cooling system - INOX

EE290076          Air purge system M44x1.5

EE290077          Air purge system unthread

EE290078          Air purge system 1”

EE290079          Air purge system 1”1/2

EE290133          Air cooling system with air purge

EE360009          BK7 window (35 x 2 mm) for EE280315

EE360066          Zaffire window (35 x 2 mm) for EE280315

EE360082          ZnSe window (35 x 2 mm) for EE280315

Flange

EE280223          AISI304 - from 1" 1/2 to 3/4" flange

EE280282          AISI304 - from 1" 1/2 to 1" 1/2 flange BSPP

EE280292          AISI304 - from 1" 1/2 to 1 " 1/4 flange

EE290113          AISI304 - from 1" 1/2 to 3/4" flange 

Sighting Tube

EE280059          AISI304 1" 1/2 L=450 mm sighting tube

EE280278          AISI304 1" 1/2 L=600 mm 1" 1/2 sighting tube

EE280280          AISI304 L=300 mm 3/4" sighting tube

EE280281          AISI304 L=150 mm 3/4" sighting tube

EE280564          AISI316 1"1/4 L=400 mm sighting tube

Packing information:

Instrument only

Size                  45 mm diameter x 200 mm

Weight (net)       0.5 kg

ProductDescriptionReleaseType
IRtec RAYOMATIC 20 / 40 / 60 / 100

Instruction manual

pdf