GreenLine 4000 (1) - AOIP, Instrumentation de test et mesure, contrôle moteur
GreenLine 4000 (2) - AOIP, Instrumentation de test et mesure, contrôle moteur

GreenLine 4000

picto fleche Hand-held industrial combustion gas analyzer with 4 sensors

GreenLine 4000 is a flue gas analyzer that measures up to 4 gases: O2, CO, NO, SO2 (pollution measurement) or CxHy. It accepts up to 10 different preloaded fuels. Further fuels can be added using GasConfig PC software.

Ask a question
Get a call

 

GreenLine 4000 is a flue gas analyzer that measures up to 4 gases: O2, CO, NO, SO2 (pollution measurement) or CxHy. It accepts up to 10 different preloaded fuels. Further fuels can be added using GasConfig PC software.

Several flue gas sampling probes are available, with different lengths and shapes, in order to meet all the requirements of the various applications. The sampling probe is connected to the instrument using a single or dual hose through a water trap and a suspended particle line filter.

GreenLine 4000 provides various additional functionalities available in option to enable comprehensive combustion gas analyses:

  • Air and boiler surface temperature measurements, using specific probes
  • Draft measurement
  • Smoke index measurement, using the optional external hand pump
  • Gas leak detection and location
  • Ionization flame tester
  • Gas velocity, using a Pitot tube adapted to the stack diameter and connected to the differential pressure ports
  • CO ambient monitoring with sound and visual alarm, using an external probe
  • Automatic CO sensor internal protection from high CO level by extension of the measuring range up to 10% CO

With gas and air temperature measurements combined to gas analyzis, GreenLine 4000 will calculate the boiler efficiency, excess air and CO2 concentration.

Key features:

  • Accepts up to 4 gas sensors in different ranges, from the basic O2, CO, NO, SO2 or CxHy
  • Measures up to 10 different fuels in standard. Other fuels can be added using GasConfig software
  • Can store up to 250 analyses
  • DBGas 2004 software package allows the operator to easily manage all of the data & analyzis information

 

Measured parameter Range Resolution GreenLine 4000
O2 From 0 to 25% vol. 0.1% EC
CO From 0 to 8000 ppm 1 ppm EC
CO From 0 to 20000 ppm 1 ppm EC
CO LOW From 0 to 500 ppm 0.1 ppm EC
CO From 0 to 10% 0.01% EC
CO2 From 0 to 99.9% 0.1% Calc
NO From 0 to 4000 ppm 1 ppm EC
NO LOW From 0 to 500 ppm 0.1 ppm EC
NOx From 0 to 4000 ppm 1 ppm Calc
NO2 From 0 to 1000 ppm 1 ppm EC
NO2 LOW From 0 to 100 ppm 0.1 ppm EC
SO2 From 0 to 4000 ppm 1 ppm EC
SO2 LOW From 0 to 500 ppm 0.1 ppm EC
CxHy From 0 to 5% 0.01% Pellistore
Efficiency From 1 to 99.9% 0.1% Calc
Excess air From 1 to infinite 0.01% Calc
Delta P ±100 hPa 0.01 hPa
Tair/Tgas -10...100°C / 0...1000°C 0.1°C Pt100 / Tc K
Calc

Further features

Zero calibration Automatic calibration procedure at instrument power-on. Fresh air inlet with electrovalve and separate pneumatic circuit
Self-diagnosis Sensor efficiency test with diagnostic page
Ambiant CO monitoring With an external probe
Gas level alarms Programmable from PC with GasConfig software
Sampling pump 1.4 l/min - 100 mbar
Smoke measurement Using the external manual pump
Printer 24 columns with 58 mm paper roll
Autonomy:, 40 reports with full battery

General specifications

Size 115 x 90 x 330 mm
Weight 1.1 kg with battery and printer
Power supply 110/230 VAC (50/60 Hz)
Battery Type: Rechargeable 7.2 Ah
Battery life: 10 hours continuous use
Charging time: 3 h at 90%
Communication ports USB
Internal test memory Up to 250 complete analyzis data points structured by boiler

Environmental specifications

Operating reference range From -5°C to +45°C (up to 50°C for short time)
Storage temperature limits From -20 to +60°C (3 months max. at temperatures exceeding the operational limits)

Instrument:

Ordering code structure: 7826 – A – B – CC – D – EEE – F – GGGGG – H / X

Please select the required options from tables A, B… below to define the right device reference.

 

7826                 GreenLine 4000

Standard delivery includes:

  • Base unit with 2 sensors (O2 + CO)
  • Li-ION battery + charger module
  • Draft and differential pressure measurement
  • Internal impact printer
  • Data memory & real time clock
  • Configuration software GasConfig
  • Data management software DBGas2004 Lite version
  • USB adapter
  • Leak test pressure decay program
  • Factory test report
  • Instruction manual
  • Warranty: 1 year

 

Table A – Sensor n°1

1                      O2 (0 - 25%)

Table B – Sensor n°2

2H                    CO (0 - 8,000 ppm) H2 compensated + Dilution system

2X                    CO (0 - 20,000 ppm)

2Y                    CO (0 - 10%)

2LO                  CO (0 - 500 ppm / res. 0.1 ppm) + Dilution system

Table C – Sensor n°3 and n°4 (2 choices mandatory)

0                      None

4                      NO (0 - 4,000 ppm / res. 1 ppm) & NOx calculation (sensor n°3 only)

4LO                  NO (0 - 500 ppm / res. 0.1 ppm) & NOx calculation (sensor n°3 only)

5                      NO2 (0 - 1000 ppm) (sensor n°4 only)

5LO                  NO2 (0 - 100 ppm) (sensor n°4 only)

6                       SO2 (0 - 4000 ppm) (sensor n°4 only)

6LO                  SO2 (0 - 500 ppm) (sensor n°4 only)

8                      CxHy (0 - 5%) (sensor n°4 only)

Table D – Sample probes - including water trap and line filter (1 choice only)

0                      None

3                      300 mm sampling dual hose probe BB610046 (Gas + Draft)  - max 800°C

5D                    750 mm sampling dual hose probe BB610080 (Gas + Draft) - max 800°C

F                      Sintered filter mounted on top of the probe, Ø8 mm - max 800°C

Table E – Options (1 and 6 mandatory)

1                      Built-in impact printer

2H                    Kit for differential pressure measurement (double hose)

3                      Leak test kit (pump + hose + adapters)

6                      Electrovalve for autozero quick start-up

Table F – Mains adapter / Charger (1 choice only)

1                      115 V (50/60 Hz) – USA plug

3                      230 V (50/60 Hz) – UK plug

4                      230 V (50/60 Hz) – European plug

5                      100 V (50/60 Hz) – USA / Japan plug

Table G – Accessories

0                      None

1                      DBGas 2004 standard software

3                      ABS rigid carrying case

3V                    Vinyl carrying case with shoulder strap

5                      Pt100 remote air temperature sensor with 2 m cable and positioning cone

B                      Manual pump for smoke index measurements + 40 filters + table

E                      300 mm Pitot probe for gas velocity measurement (BB610032)

Table H – Calibration certificate

1                      Factory certificate (gas + pressure + temperature)

Table X – Customization

INTL                 English language - manual in English - English keyboard

USA                  English language - manual in English - English keyboard

FR                    French language - manual in French - French keyboard

HOL                  Dutch language - manual in English - English keyboard

POL                  Polish language - manual in English - English keyboard

SPA                  Spanish language - manual in English - English keyboard

UK                    English language - manual in English - English Kkyboard

Accessories:

Probes and sensors:

BB610046          300 mm sampling dual hose probe BB610046 (Gas + Draft) - max 800°C

BB610080          750 mm sampling dual hose probe BB610080 (Gas + Draft) - max 800°C

BB830018          Pt100 remote air temperature sensor, with 2 m cable and positioning cone

BB830025          External probe for natural boiler draft (200 Pa)

BB610032          300 mm Pitot probe for gas velocity measurement

BB610033          700 mm Pitot probe for gas velocity measurement

BB610034          1000 mm Pitot probe for gas velocity measurement

F2132100          130 mm air TC K-type probe

F2137100          130 mm contact TC K-type probe

F2139000          Pipe Velcro TC K-type probe

F2139100          Tc K-type clamp temperature probe

F2139200          Pt100 clamp temperature probe

BB610057          3 m extension for dual hose probe and Tc

BB610103          6 m extension for dual hose probe and Tc

Test tools and miscellaneous:

EE300088          Single hose pressure probe and burner hose kit

EE300248          Kit for detecting leaks in gas networks (pump + hose + adapters)

F7828000          Manual pump for smoke index measurements + 40 filters + table

Software and connectors:

BB260166          DBGas 2004 standard software

EE700476          USB adaptator cable

Transport cases and protections:

BB880028          ABS rigid carrying case

BB880043          Vinyl carrying case with shoulder strap

EE880047          Rubber holster with magnetic support

Consumable parts:

EE340005          Printer paper roll - Minimum order of 10 pcs

EE490002          Printer ribbon - Minimum order of 3 pcs

EE650011          Filter for soot (40 pieces per pack)

EE650074          Filter cartridge for EE650076 / EE 650082 water trap + filter - Minimum order of 10 pcs

Product Description Release Type
DBGas 2004

Data management software under Windows©

4.0.18 zip
DBGas 2004

Instruction manual

MM850523-K12
GasConfig

Configuration software under Windows©

2.0.22 zip
GreenLine 4000 / UniGas 3000

Instruction manual

MM850402-K12 pdf