UniGas 2000 (1) - AOIP, Instrumentation de test et mesure, contrôle moteur
UniGas 2000 (2) - AOIP, Instrumentation de test et mesure, contrôle moteur
UniGas 2000 (3) - AOIP, Instrumentation de test et mesure, contrôle moteur
UniGas 2000 (4) - AOIP, Instrumentation de test et mesure, contrôle moteur
UniGas 2000 (5) - AOIP, Instrumentation de test et mesure, contrôle moteur
UniGas 2000 (6) - AOIP, Instrumentation de test et mesure, contrôle moteur
UniGas 2000 (7) - AOIP, Instrumentation de test et mesure, contrôle moteur

UniGas 2000

picto fleche Hand-held combustion gas analyzer with 3 sensors

Unigas 2000+ is a professional flue gas analyser for 3 gases: O2, CO & NO with electrochemical sensors, plus CO2 and NOx calculated.

Ask a question
Get a call

UniGas 2000 is a professional flue gas analyser for 3 gases: O2, CO & NO with electrochemical sensors, plus CO2 and NOx calculated.

This gas analyser provides data for up to 10 fuels for calculating combustion values. It is equipped with audible alarms on gases measurement.

Flue gas sampling probes with different lengths and shapes are available to meet every specific requirement. The sampling probe is connected to the instrument with a single or dual hose, a water trap and a suspended particle filter.

The instrument is delivered with a built-in rugged impact printer. The analyser and its internal printer are powered by the same internal battery. Charger is supplied as standard.

Smoke index measurement is performed by using the optional external hand pump (ref: F7828000). The results can be stored in the internal memory and printed on the report.

A procedure can be selected to monitor the CO in ambient air using the internal sensors. An internal program allows CO max measurement in atmospheric boiler room test with 15 values logging.

Measured parameter Range Resolution UniGas 2000
O2 From 0 to 25 % vol. 0.1 % EC
CO From 0 to 8000 ppm 1 ppm EC
CO2 From 0 to 99.9 % 0.1 % Calc
NO From 0 to 4000 ppm 1 ppm EC
NOx From 0 to 4000 ppm 1 ppm Calc
Efficiency From 1 to 99.9 % 0.1 % Calc
Excess air From 1 to infinite 0.01 % Calc
Pressure / Draft From -10 to 120 hPa 0.01 hPa
Tair/Tgas -10...100°C/ 0...600°C 0.1°C Pt100 / Tc K
Calc

Further features

Zero calibration Automatic calibration procedure at instrument power-on. Fresh air inlet with electrovalve and separate pneumatic circuit
Self-diagnosis Sensor efficiency test with diagnostic page
Gas level alarms Programmable from PC with GasConfig software
Sampling pump 1.4 l/min - -100 mbar
Smoke measurement Using the external manual pump
Printer 24 columns with 58 mm paper roll
Autonomy:, 40 reports with full battery

General specifications

Size 115 x 90 x 330 mm
Weight 1.1 kg with battery and printer
Power supply 110/230 Vac – 50 / 60 Hz
Battery Type: Rechargeable Li-ION
Battery life: 6 hours continuous use
Charging time: 8 h at 90%
Communication ports RS 232
USB in option
Internal test memory Up to 250 complete analysis data points structured by boiler

Environmental specifications

Operating reference range From -5°C to +45°C (up to 50°C for short time)
Storage temperature limits From -20 to +50°C (3 months max. at temperatures exceeding the operational limits)

Instrument:

Ordering code structure: 7822 – A – BB – C – DDDDD – E – FF – G / X

Please select the required options from tables A, B… below to define the right device reference. 

7822                 UniGas 2000

Standard delivery includes:

  • Base unit with 2 sensors (O2 + CO)
  • Li-ION battery + charger module
  • Internal impact printer
  • IR port for thermal printer
  • Draft and differential pressure measurement
  • Configuration software GasConfig
  • Data management software DBGas2004 Lite version
  • USB adapter
  • Factory test report
  • Instruction manual
  • Warranty: 1 year

Table A – Sensor n°1

1                      O2 (0 - 25 %)

 

Table B – Sensor n°2 and n°3 (2H is mandatory)

2H                    CO (0 - 8,000 ppm) H2 compensated + Dilution system

4                      NO (0 - 4,000 ppm / res. 1 ppm) & NOx calculation (sensor n°3 only)

 

Table C – Sample probes - including water trap and line filter (1 choice only)

0                      None

1                      180 mm sampling dual hose probe BB610051 (Gas + Draft) - max 800°C

2                      300 mm sampling dual hose probe BB610046 (Gas + Draft) - max 800°C

 

Table D – Options (P is mandatory)

P                      Built-in impact printer

1                      Pressure decay program firmware + gas network leak test kit

2                      Internal sensor for gas leak detector (sniffer)

6                      DBGas 2004 standard software

8                      Pt100 remote air temperature sensor (2 m cable) + positioning cone

9                      Differential pressure connection kit (2 x EE300088

 

Table E – Mains adapter / Charger (1 choice only)

1                      115 V – 50 / 60 Hz – USA plug

3                      230 V – 50 / 60 Hz – UK plug

4                      230 V – 50 / 60 Hz – European plug

5                      100 V – 50 / 60 Hz – USA / Japan plug

 

Table F – Accessories

0                      None

3                      Vinyl carrying case with shoulder strap

4                      ABS rigid carrying case

6                      Manual pump for smoke index measurements + 40 filters + table

 

Table G – Calibration certificate

1                      Factory certificate (gas + pressure + temperature)

 

Table X – Customization

INTL                 English language - manual in English - English Keyboard

USA                 English language - manual in English - English Keyboard

FR                   French language - manual in French - French Keyboard

HOL                 Dutch language - manual in English - English Keyboard

POL                  Polish language - manual in English - English Keyboard

SPA                  Spanish language - manual in English - English Keyboard

UK                   English language - manual in English - English Keyboard

Accessories:

Probes and sensors:

BB610051          180 mm sampling dual hose probe BB610051 (Gas + Draft) - max 800°C

BB610046          300 mm sampling dual hose probe BB610046 (Gas + Draft) - max 800°C

BB830018          Pt100 remote air temperature sensor, with 2 m cable and positioning cone

BB830025          External probe for natural boiler draft (200 Pa)

F2132100          130 mm air TC K-type probe

F2137100          130 mm contact TC K-type probe

F2139000          Pipe Velcro TC K-type probe

F2139100          Tc K-type clamp temperature probe

F2139200          Pt100 clamp temperature probe

BB610057          3 m extension for dual hose probe and Tc

BB610103          6 m extension for dual hose probe and Tc

Test tools and miscellaneous:

EE300088          Single hose pressure probe and burner hose kit

EE300248          Kit for detecting leaks in gas networks (pump + hose + adapters)

F7828000          Manual pump for smoke index measurements + 40 filters + table

Software and connectors:

BB260166          DBGas 2004 standard software

EE700476          USB adaptator cable 

Transport cases and protections:

BB880028          ABS rigid carrying case

BB880043          Vinyl carrying case with shoulder strap

EE880047          Rubber holster with magnetic support

Consumable parts:

EE340006          Printer paper roll - Minimum order of 10 pcs

EE490002          Printer ribbon - Minimum order of 3 pcs

EE650011          Filter for soot (40 pieces per pack)

EE650074          Filter cartridge for EE650076 / EE 650082 water trap + filter -        Minimum order of 10 pcs

Product Description Release Type
DBGas 2004

Data management software under Windows©

4.0.18 zip
DBGas 2004

Instruction manual

MM850523-K12
GasConfig

Configuration software under Windows©

2.0.22 zip
GreenLine 2000 / UniGas 2000

Instruction manual

MM850404-K12 pdf