GreenLine 6000 is a flue gas analyzer that measures up to 6 gases: O2, CO, NO, NO2, SO, CxHy with electrochemical sensors, and can calculate others like CO2. It accepts up to 10 different preloaded fuels. Further fuels can be added using GasConfig PC software.
Several flue gas sampling probes are available, with different lengths and shapes, in order to match all the requirements of various applications. The sampling probe is connected to the instrument using a single or dual hose through a water trap and a suspended particle line filter. An optional heated industrial gas probe with heated hose is recommended for long-term high temperature measurements to dry the flue gas and avoid dilution of NO2 and SO2. A sintered pre‐filter is suggested for severe and heavy applications.
The gas analyzer is made of two parts communicating through cable or Bluetooth protocol: the Main Control Unit (MCU) and the Remote Control Unit (RCU). The MCU takes in charge gas analyzis while the RCU is used to display the measured data, store the analyzis in its internal memory, print out any data using the built-in impact printer and transfer data to computer.
GreenLine 6000 provides various additional functionalities available in option to enable comprehensive combustion gas analyses:
- Air and boiler surface temperature measurements, using specific probes
- Draft measurement
- Automatic CO sensor internal protection from high CO level by extension of the measuring range up to 10% CO
- Flow measurement: Measuring the flow of gas extracted from the boiler and adjusting the pump in order to obtain a constant sampling volume
- Differential pressure measurement: Measuring pressure at the burner and checking stack draft
- Two 4-20 mA inputs
- Smoke index measurement: Checking the presence of soot in gas pipes behind the heat exchanger, with a manual smoke pump, smoke index reference table and paper filter.
- Gas velocity measurement, using a Pitot tube
- Gas leak detection, using a leak test kit
With gas and air temperature measurements combined to gas analyzis, GreenLine 4000 will calculate the boiler efficiency, excess air and CO2 concentration.
Key features:
- Accepts up to 6 gas sensors in different ranges, O2, CO, NO, NO2, SO, CxHy
- Measures up to 10 different fuels in standard. Other fuels can be added using GasConfig software
- Up to 6 sound and visual alarms if set limits of gas type and levels are exceeded.
- DBGas 2004 software package allows the operator to easily manage all of the data & analyzis information
Instrument:
Ordering code structure: 7846 – A – B – C – D – E – F – L – M – NNNNN – P / X
Please select the required options from tables A, B… below to define the right device reference.
7846 GreenLine 6000
Standard delivery includes:
- Base unit with 2 sensors (O2 + CO)
- Li-ION battery + charger module
- Internal impact printer
- 1,000 data memory & real time clock
- Configuration software GasConfig
- Data management software DBGas2004 Lite version
- USB adapter
- Draft and differential pressure measurement
- Remote module with 2.5 m long shielded cable
- Factory test report
- Instruction manual
- Warranty: 1 year
OR
7846WL GreenLine 6000 Wireless (Bluetooth MCU/RCU)
Table A – SENSOR No. 1
1 O2 (0 - 25%)
Table B – SENSOR No. 2
2H CO (0 - 8,000 ppm) H2 compensated + Dilution system
2X CO (0 - 20,000 ppm)
2LO CO (0 - 500 ppm / res. 0.1 ppm) + Dilution system
Table C – SENSOR No. 3
0 None
4 NO (0 - 4,000 ppm / res. 1 ppm) & NOx calculation
4LO NO (0 - 500 ppm / res. 0.1 ppm) & NOx calculation
Table D – SENSOR No. 4
0 None
5 NO2 (0 - 1,000 ppm)
5LO NO2 (0 - 100 ppm)
8 CxHy (0 - 5%)
Table E – SENSOR No. 5
0 None
6 SO2 (0 - 4,000 ppm)
8 CxHy (0 - 5%)
Table F – SENSOR No. 6
0 None
7 CO% (0 - 10%)
8 CxHy (0 - 5%)
9 H2S (0 - 1,000 ppm)
Table L – Sample probes
0 None
1 Ø8 / 300 mm gas + draft probe (dual hose)
2P Ø10 / 750 mm gas + draft probe (dual hose) removable tip
3P Ø10 / 1500 mm gas + draft probe (dual hose) removable tip
2SP Ø10 / 750 mm heated* gas + draft probe (dual hose) removable tip
3SP Ø10 / 1500 mm heated* gas + draft probe (dual hose) removable tip
F10 Sintered filter for 2, 3, S & P probes Ø10 mm
* Heated gas probe used for smoke index measurement.
Table M – Mains adapter / Charger
1 115 V (50/60 Hz) – USA plug
2 230 V (50/60 Hz) – Schuko plug
3 230 V (50/60 Hz) – UK plug
4 230 V (50/60 Hz) – European plug
5 100 V (50/60 Hz) – USA / Japan plug
Table N – Accessories
0 None
1 DBGas 2004 standard software
2 300 mm Pitot tube
3 750 mm Pitot tube
4 Pt100 remote combustion air temperature probe, length: 2 m
Table P – Calibration certificate
1 Factory certificate (gas + pressure + temperature)
Table X – Customization
INTL English language - manual in English - English keyboard
USA English language - manual in English - English keyboard
FR French language - manual in French - French keyboard
HOL Dutch language - manual in English - English keyboard
POL Polish language - manual in English - English keyboard
SPA Spanish language - manual in English - English keyboard
UK English language - manual in English - English keyboard
Accessories:
Probes and sensors:
BB830006 Pt100 remote air sensor + positioning cone (with 2 m cable)
BB830025 External probe for natural boiler draft (200 Pa)
BB610032 Pitot tube 300 mm
BB610033 Pitot tube 800 mm
BB610034 Pitot tube 1000 mm
EE610106 Ø8 / 300 mm tip (max. 800°C)
EE610105 Ø8 / 750 mm tip (max. 800°C)
EE610015 Ø8 / 1000 mm tip (max. 800°C)
EE610104 Ø8 / 1500 mm tip (max. 800°C)
EE610098 Ø10 / 300 mm tip (P option)
EE610102 Ø10 / 750 mm tip (P option)
EE610029 Ø10 / 1000 mm tip (P or SP option)
EE610100 Ø10 / 1500 mm tip (P option)
BB610058 Ø8 / 300 mm gas or draft probe (dual hose)
BB610066 Ø10 / 750 mm gas + draft probe (dual hose) removable tip
BB610067 Ø10 / 1500 mm gas + draft probe (dual hose) removable tip
BB610068 Ø10 / 750 mm heated gas + draft probe (dual hose) removable tip
BB610069 Ø10 / 1500 mm heated gas + draft probe (dual hose) removable tip
F2132100 130 mm air TC K-type probe
F2137100 130 mm contact TC K-type probe
F2139000 Pipe Velcro TC K-type probe
Consult us 3 m extension for dual hose probe and Tc
Consult us 6 m extension for dual hose probe and Tc
Test tools and miscellaneous:
EE300088 Single hose pressure probe and burner hose kit
EE300248 Kit for detecting leaks in gas networks (pump + hose + adapters)
F7828000 Manual pump for smoke index measurements + 40 filters + table
Software and connectors:
BB260166 DBGas 2004 standard software
Consumable parts:
EE340005 Printer paper roll - Minimum order of 10 pcs
EE490002 Printer ribbon - Minimum order of 3 pcs
EE650072 Line and autozero filter cartridge - Minimum order of 10 pcs
EE650073 NOx / SOx filter cartridge - Minimum order of 10 pcs
EE650074 Filter cartridge for EE650076 / EE 650082 water trap + filter - Minimum order of 10 pcs
EE650091 Quartz filter for heated head probe - Minimum order of 3 pcs
EE650099 Sintered filter for Ø10 mm tip
EE650100 Sintered filter for Ø8 mm tip
Packing information:
Size: Main Control Unit: 455 x 205 x 365 mm
Hand-Held Remote Control Unit: 115 x 90 x 330 mm
Weight: Main Control Unit: 10 kg
Hand-Held Remote Control Unit: 0.9 kg