GreenLine 6000 (1) - AOIP, Instrumentation de test et mesure, contrôle moteur

GreenLine 6000

picto fleche Hand-held industrial combustion gas analyzer with 6 sensors

GreenLine 6000 is a flue gas analyzer that measures up to 6 gases: O2, CO, NO, NO2, SO, CxHy with electrochemical sensors, and can calculate others like CO2. It accepts up to 10 different preloaded fuels. Further fuels can be added using GasConfig PC software.

Ask a question
Get a call

GreenLine 6000 is a flue gas analyzer that measures up to 6 gases: O2, CO, NO, NO2, SO, CxHy with electrochemical sensors, and can calculate others like CO2. It accepts up to 10 different preloaded fuels. Further fuels can be added using GasConfig PC software.

Several flue gas sampling probes are available, with different lengths and shapes, in order to match all the requirements of various applications. The sampling probe is connected to the instrument using a single or dual hose through a water trap and a suspended particle line filter. An optional heated industrial gas probe with heated hose is recommended for long-term high temperature measurements to dry the flue gas and avoid dilution of NO2 and SO2. A sintered pre‐filter is suggested for severe and heavy applications.

The gas analyzer is made of two parts communicating through cable or Bluetooth protocol: the Main Control Unit (MCU) and the Remote Control Unit (RCU). The MCU takes in charge gas analyzis while the RCU is used to display the measured data, store the analyzis in its internal memory, print out any data using the built-in impact printer and transfer data to computer.

GreenLine 6000 provides various additional functionalities available in option to enable comprehensive combustion gas analyses:

  • Air and boiler surface temperature measurements, using specific probes
  • Draft measurement
  • Automatic CO sensor internal protection from high CO level by extension of the measuring range up to 10% CO
  • Flow measurement: Measuring the flow of gas extracted from the boiler and adjusting the pump in order to obtain a constant sampling volume
  • Differential pressure measurement:  Measuring pressure at the burner and checking stack draft
  • Two 4-20 mA inputs
  • Smoke index measurement: Checking the presence of soot in gas pipes behind the heat exchanger, with a manual smoke pump, smoke index reference table and paper filter.
  • Gas velocity measurement, using a Pitot tube
  • Gas leak detection, using a leak test kit

With gas and air temperature measurements combined to gas analyzis, GreenLine 4000 will calculate the boiler efficiency, excess air and CO2 concentration.

Key features:

  • Accepts up to 6 gas sensors in different ranges, O2, CO, NO, NO2, SO, CxHy
  • Measures up to 10 different fuels in standard. Other fuels can be added using GasConfig software
  • Up to 6 sound and visual alarms if set limits of gas type and levels are exceeded.
  • DBGas 2004 software package allows the operator to easily manage all of the data & analyzis information