ICO 51 (1) - AOIP, Instrumentation de test et mesure, contrôle moteur
ICO 51 (2) - AOIP, Instrumentation de test et mesure, contrôle moteur

ICO 51

picto fleche Programmable digital panel meter for electrical measurements

ICO 51 is a programmable 10,000-point digital panel meter 72 x 24 mm for electrical measurements.

Ask a question
Get a call

ICO 51 is a programmable digital panel meter 72 x 24 mm for electrical measurements in 10,000 points. It allows DC and AC voltage to be measured up to 400 V (true effective value with or without component continuous health) and DC and AC current to be measured up to 5 A using a small shunt screwed on the back connector.

  • Panel meter size: 72 mm x 24 mm
  • IP65 protected
  • Measurement, display and scaling of:
    • DC and AC voltage up to 400 V
    • DC current up to 2,000 A with an external shunt
    • AC current up to 200 A + Current transformer, with secondary current of 1 A or 5 A
    • Frequency up to 5,000 Hz
  • 9 different power supplies available

Electrical measurement indicator

Type Range Resolution Accuracy (1 year)
(23°C ±1°C)
Input impedance
DC voltage 500 mV
5 V
50 V
400 V
100 μV
1 mV
10 mV
100 mV
0.1% + 100 μV
0.1% + 1 mV
0.1% + 10 mV
0.1% + 0.1 V
> 100 MΩ
1.1 MΩ
1 MΩ
1 MΩ
AC voltage 500 mV
5 V
50 V
400 V
100 μV
1 mV
10 mV
100 mV
0.7% + 1 mV
0.5% + 6 mV
0.5% + 60 mV
0.5% + 0.6 V
1 MΩ
1 MΩ
1 MΩ
1 MΩ
DC current 4-20 mA or 0-50 mA
1 A (2)
5 A (2)
10 µA
1 mA
1 mA
0.2% + 10 µA

shunt 10 Ω included
external shunt 100 mV
external shunt 100 mV

AC current 1 A (2)
5 A (2)

1 mA
1 mA

  external shunt 100 mV
external shunt 100 mV

Temperature coefficient: ≤ 10% accuracy/°C

Continuous mode: -40 to 100 % range.
Alternate mode: 4 to 100 % range from 25 to 500 Hz without D.C component (possible measurements up to 10 kHz on some ranges with less precision).

(1) Extended measurement range: -40 to +110% range.
(2) With external shunts
Common rejection mode: ³ 110 dB at 50 Hz on 500 mV DC range
Acceptable maximum voltage on voltage range: 600 V.
Acceptable maximum voltage: 250 V~ in common mode.

Automatic ranging

Further features

Measurement hold Short-circuit on the rear panel
Scaling The value is to be entered using keyboard, while the value of measurement corresponding can be is introduced of the same way, is measured by the instrument.
This possibility is very interesting for error corrections on temperature ranges.
Sampling rate 2.5 samples / s

General specifications

Size 99 x 36 x 120 mm
Weight 300 g
Display From -1999 to 9999 with 14 mm red, yellow or green indication LED
Supply 230 V at ±10% (50/60 Hz)
Other power supplies available in option

Environmental specifications

Reference range 23°C ±1°C (20 to 75 % w/o condensing)
Operating reference range 0 to 50°C (RH: 20 to 75 % w/o condensing)
Limit operating range -10°C to +50°C (RH: 10 to 80 % w/o condensing)
Indice de protection IP40 in ABS case
IP65 in watertight metallic case

 

Instrument:

Ordering reference code: ICO51-Isolated power supply-Display-Enclosure

Isolated power supply:

48 V~                    9

230 V~                   8

115 V~                   7

24 V~                    6

36 to 72 V-             5

18 to 36 V-             4

9 to 18 V-               3

5 V-                       2

 

Display:

Red                       R

Green                    V

 

Enclosure:

Plastic                   P

Metal                     M

Accessories:

AN8002                 Cold Junction Compensation Module

AN8003                 Shunt 1 A - 100 mV

AN8004                 Shunt 5 A - 100 mV

AN8005                 Shunt 4-20 mA (50 ohms)

AN5844                 Current transformer 2/1 A

AN5845                 Current transformer 20/1 A

AN5846                 Current transformer 200/1 A

ER42062-001          RC protection circuit

AMD002-000: Current transformer 20/5A

AMD003-000: Current transformer 200/5 A

Product Description Release Type
ICO 51

Instruction manual

NT 46026-100D pdf
VISULOG

Instruction manual

pdf
VISULOG WEB

For remote access to VISULOG software

1.5B exe