ICO 62
Programmable digital panel meter for temperature and process signals
ICO 62 is a 10,000-point programmable digital panel meter 96 x 24 mm for temperature, process voltage and process current measurements.
ICO 62 is a 10,000-point programmable digital panel meter 96 x 24 mm for temperature, process voltage and process current measurements.
ICO 62 is a 10,000 programmable digital panel meter 96 x 24 mm for temperature, process voltage and process current measurements. It can be used together with temperature sensors, either resistive probes Pt or thermocouples. It is possible to change the configuration of measurement type, range, limits and scaling.
The configuration of these parameters is protected against any inopportune modifications.
Type | Range (1) | Resolution | Accuracy (1 year) (23°C ±1°C) |
Comments |
DC voltage | >50 mV 500 mV 5 V 50 V |
>10 µV 100 μV 1 mV 10 mV |
>0.1% + 10 μV 0.1% + 100 μV 0.1% + 1 mV 0.1% + 10 mV |
Input impedance > 1000 MΩ > 1000 MΩ 1 MΩ 1 MΩ |
DC current | 4-20 mA or 0-50 mA | 10 µA | 0.2% + 10 µA | 10 Ω shunt |
AC current | 1 A (2) 5 A (2) |
1 mA 1 mA |
Measuring current 200 µA |
Temperature coefficient: ≤ 10% accuracy/°C
Automatic ranging
(1) Extended measurement range: -40 to +110% range.
Type | Range (1) | Resolution | Accuracy over 1 year (23°C ±1°C) (2) |
Pt100 | -200 to +500°C -220 to +1200°C |
0.1°C 1°C |
0.1% RDG + 0.2°C 0.1% RDG + 2°C |
Pt1000 | -200 to +500°C | 0.1°C | 0.1% RDG + 0.2°C |
Tc K | -100 to +1000°C +1000 to 1372°C |
0.1°C 1°C |
0.1% RDG + 0.4°C 0.1% RDG + 1°C |
Tc T | -100 to +400°C | 0.1°C | 0.1% RDG + 0.4°C |
Tc Platine | -100 to +1400°C | 0.1°C | 0.1% RDG + 0.4°C |
Tc J | -120 to +999°C | 0.1°C | 0.1% RDG + 0.4°C |
Tc L | -40 to +900°C | 0.1°C | 0.1% RDG + 0.4°C |
Tc R | -50 to +120°C +120 to 1768°C |
1°C 1°C |
0.1% RDG + 2°C 0.1% RDG + 1°C |
Tc S | -50 to +450°C +450 to 1768°C |
1°C 1°C |
0.1% RDG + 2°C 0.1% RDG + 1°C |
Temperature coefficient: ≤ 10% accuracy/°C
Display in °C or °F.
(1) For a defined type of sensor, the commutation of range and the change of resolution can be automatic.
Measurement range extendable.
(2) Accuracy given without reference junction.
The typical error brought by the reference junction (AN8002) is 0.3°C.
Measurement hold | Short-circuit on the rear panel |
Statistics | Memorizing of maximum and minimum values |
Scaling | The value is to be entered using keyboard, while the value of measurement corresponding can be is introduced of the same way, is measured by the instrument. This possibility is very interesting for error corrections on temperature ranges. |
Sampling rate | 2.5 samples / s |
Size | 99 x 36 x 120 mm |
Weight | 300 g |
Display | From -1999 to 9999 with 14 mm red, yellow or green indication LED |
Supply | 230 V at ±10% (50/60 Hz) Other power supplies available in option |
Reference range | 23°C ±1°C (20 to 75 % w/o condensing) |
Operating reference range | 0 to 50°C (RH: 20 to 75 % w/o condensing) |
Limit operating range | -10°C to +50°C (RH: 10 to 80 % w/o condensing) |
Indice de protection | IP40 in ABS case IP65 in watertight metallic case |
Protections | - Protection of unit programming by access code. - Protection of the threshold values by safety function programming |
Ordering reference code: ICO52-Power supply-Display-Enclosure
Power supply:
48 V~ 9
230 V~ 8
115 V~ 7
24 V~ 6
36 to 72 V- 5
18 to 36 V- 4
9 to 18 V- 3
5 V- 2
Display:
Red R
Green V
AN8002 Cold Junction Compensation Module
AN8003 Shunt 1 A - 100 mV
AN8004 Shunt 5 A - 100 mV
AN8005 Shunt 4-20 mA (50 ohms)
AN5844 Current transformer 2/1 A
AN5845 Current transformer 20/1 A
AN5846 Current transformer 200/1 A
ER42062-001 RC protection circuit
AOIP offers a complete range of services: technical assistance and advice, calibration and verification by the SOFIA laboratory, equipment repair, maintenance, assistance and metrological monitoring, equipment rental, training, installation and commissioning of your equipment. More informations